ASTM E 415 Sparks – Spectral analysis of low and unalloyed steels

ASTM E 415 2017: With our modern spark spectrometer we determine the chemical composition of unknown metals and alloys with high precision. The stationary metal analyzer SpektroMaxx from the company Spectro.
For spectral analysis, we take small samples from your workpieces, which are then analyzed in the spectrometer. Smaller components can also be analyzed directly.

Spark spectral analysis of low and unalloyed steels to determine the elemental composition. Accredited for the following concentration ranges (in mass %)

Element Min Max
carbon 1,90 3,80
Chromium 0,025 2,00
Copper 0,015 0,75
molybdenum 0,01 1,20
Manganese 0,03 1,80
Nickel 0,02 2,00
Phosphorus 0,00 0,40
silicon 0,15 2,50
sulfur 0,01 0,08
tin 0,004 0,12
vanadium 0,008 0,22